CAUTION
1. CARBON FILTER FLUSHING
After the installation or changing carbon filter. Manual Flushing Valve shall be opened for 2~3 min before operation. (process: water flow for 2~3 min)
2. AUTO FLUSHING (RO MEMBRANE)
INSTALLATION STEP
1. Tubing connections on the back of products should be connected with each usage. (Inlet Water, Drink Water, Tank, Drain) But, If the tank is not a pressure tank, water, level switch must be set the tank separately.
2. Carbon filter needs to be flushing with a manual flushing valve for 2~3 min the initial installation.
3. Set the local time of timer for the BYPASS and BYPASS TIME you want.
4. Turn on the system.
5. Once pressure tank is filled up water and the system is automatically stopped. Faucet shall be opened and the stored water shall be out of the tank.
RO MEMBRANE
Membrane Type: Polyamide Thin-film Composite
Maximum Operating Temperature: 113’F (45’C)
Maximum Operating Pressure: 125psi (8.6bar)
Permeation flow rate(GPD) of RO membrane depends on the quality of raw water.
HCRO-400G COMPONENTS |
PART NAME | DESCRIPTION | Q’TY | PRESSURE GAUGE | Measure Range: 0~1 Mpa | 2 | FLOWMETER | 0~150 LPH (Liter Per Hour) | 1 | TDS METER | Raw water & Drinking water | 1 | EMERGENCY SWITCH | DC : 24V / 12A, AC : 250V / 6A | 1 | ON-OFF SWITCH | 250V / 16A | 1 | CIRCUIT BREAKER | MCCB: Molded case circuit breaker. 10A | 1 | AC-DC Adaptor | 110-240V, 50~60Hz, 3.0A (for RO PUMP) | 1 | AUTO Flushing | Auto flushing controller | 1 | SOLENOID VALVE | DC 24C, 1/4″ | 2 | LOW PRESSURE S/W | 1/4″ | 1 | HIGH PRESSURE S/W | 1/4″ | 1 | CHECK VALVE | 1/4″ | 3 | FLOW RESTRICTOR | Control Valve | 1 | RO PUMP | DC24V, 0.9A, 70-90PSI | 2 | BALL VALVE | Manual Flushing valve (for Carbon Filter Flushing) | 1 | MEMBRANE | 150G | 3 |
|
HCRO-600G COMPONENTS |
PART NAME | DESCRIPTION | Q’TY | PRESSURE GAUGE | Measure Range: 0~1 Mpa | 2 | FLOWMETER | 0~150 LPH (Liter Per Hour) | 1 | TDS METER | Raw water & Drinking water | 1 | EMERGENCY SWITCH | DC : 24V / 12A, AC : 250V / 6A | 1 | ON-OFF SWITCH | 250V / 16A | 1 | CIRCUIT BREAKER | MCCB: Molded case circuit breaker. 10A | 1 | AC-DC Adaptor | 110-240V, 50~60Hz, 3.0A (for RO PUMP) | 1 | AUTO Flushing | Auto flushing controller | 1 | SOLENOID VALVE | DC 24C, 1/4″ | 2 | LOW PRESSURE S/W | 1/4″ | 1 | HIGH PRESSURE S/W | 1/4″ | 1 | CHECK VALVE | 1/4″ | 3 | FLOW RESTRICTOR | Control Valve | 1 | RO PUMP | DC24V, 0.9A, 70-90PSI | 2 | BALL VALVE | Manual Flushing valve (for Carbon Filter Flushing) | 1 | MEMBRANE | 300G | 2 |
|
HCRO-900G COMPONENTS |
PART NAME | DESCRIPTION | Q’TY | PRESSURE GAUGE | Measure Range: 0~1 Mpa | 2 | FLOWMETER | 0~150 LPH (Liter Per Hour) | 1 | TDS METER | Raw water & Drinking water | 1 | EMERGENCY SWITCH | DC : 24V / 12A, AC : 250V / 6A | 1 | ON-OFF SWITCH | 250V / 16A | 1 | CIRCUIT BREAKER | MCCB: Molded case circuit breaker. 10A | 1 | AC-DC Adaptor | 110-240V, 50~60Hz, 3.0A (for RO PUMP) | 1 | AUTO Flushing | Auto flushing controller | 1 | SOLENOID VALVE | DC 24C, 1/4″ | 2 | LOW PRESSURE S/W | 1/4″ | 1 | HIGH PRESSURE S/W | 1/4″ | 1 | CHECK VALVE | 1/4″ | 3 | FLOW RESTRICTOR | Control Valve | 1 | RO PUMP | DC24V, 0.9A, 70-90PSI | 2 | BALL VALVE | Manual Flushing valve (for Carbon Filter Flushing) | 1 | MEMBRANE | 300G | 3 |
|